Zurn Wilkins 114-975XL2 1-1/4" RPZ Backflow Preventer - Reduced Pressure - Lead-Free

Zurn WilkinsSKU: ZUR-114-975XL2

Price:
Sale Price$ 18,876.00 MXN
Stock:
In Stock
Description
Zurn Wilkins 114-975XL2 1-1/4" RPZ Backflow Preventer - Reduced Pressure - Lead-Free

Zurn Wilkins 114-975XL2 1-1/4" Lead-Free RPZ Backflow Preventer, Reduced Pressure Type - Premium Water Protection Solution.

Product Overview:

The Zurn Wilkins 114-975XL2 1.25" Reduced Pressure Principle Backflow Preventer is a lead-free, high-performance water safety device designed to protect potable water systems from contamination caused by backsiphonage and backpressure. Featuring a compact wye-pattern design, this low-maintenance and installer-preferred RPZA valve offers seamless integration into various residential, commercial, and industrial applications where lead-free compliance is required.

Key Features & Benefits:

Wye-Pattern Design – Reduces lay length, making installation and replacement easier
Short Lay Length – Lowers labor costs for quick and efficient replacements
Lead-Free Compliance – Meets NSF/ANSI 61 low-lead requirements for safe water applications
Serviceable In-Line – Access check valves without removing the relief valve or entire unit
Durable Construction – Built with low-lead cast bronze and corrosion-resistant materials
Versatile Installation Options – Indoor installations can include an air gap adapter and monitor switch
Certified & Compliant – Exceeds industry standards for backflow prevention

Available Sizes:

Application & Use Cases:

Designed for potable water systems, this RPZ backflow preventer is ideal for:
Municipal water supplies
Irrigation systems
Fire protection systems
Commercial and industrial plumbing systems
Residential water safety applications

This low-lead model is required in areas where lead-free valves are mandated, ensuring compliance with local plumbing codes and health regulations.

Installation Guidelines:

📌 Complies with local plumbing codes for optimal performance
📌 Mounting height: 12” (305mm) to 30” (762mm) above a proper drain
📌 Ensure adequate clearance for testing and maintenance
📌 Must not be submerged to prevent damage or malfunction

💡 Pro Tip: Install in accordance with the Uniform Plumbing Code and manufacturer recommendations for maximum efficiency.

Technical Specifications:

Max. Working Pressure: 175 psi
Max. Working Temperature: 180°F
Hydrostatic Test Pressure: 350 psi
End Connections: Threaded FNPT ANSI B1.20.1
Lead-Free Compliant: Yes! NSF 61 Certified

🔧 Reliable performance in high-pressure water systems!

Industry Certifications & Compliance:

ASSE® Listed 1013
IAPMO® Listed
CSA® Certified B64.4
AWWA Compliant C511
NSF/ANSI 61 Certified (0.25% MAX weighted average lead content)
UL® Classified (without shut-off valves or with OS&Y valves)
C-UL® Classified
Approved by the Foundation for Cross-Connection Control & Hydraulic Research at USC

Premium Materials for Long-Lasting Performance:

Main Valve Body: Low Lead Cast Bronze (ASTM B 584)
Access Covers: Low Lead Cast Bronze (ASTM B 584)
Fasteners: Stainless Steel (300 Series)
Elastomers: FDA-Approved Silicone & Buna Nitrile
Internals: Delrin & Nylon (NSF Listed)
Polymers: Noryl™
Springs: Stainless Steel (300 Series)
Ball Valve Handles: Stainless Steel

Why Choose the Zurn Wilkins 114-975XL2 RPZ?

Superior Protection – Prevents water contamination from backflow hazards
Quick & Easy Maintenance – Top-access check valves for in-line servicing
Trusted by Professionals – Installer-preferred design for seamless integration
Lead-Free Compliance – Safe for use in potable water systems
Industry-Leading Certifications – Exceeds standards for backflow prevention

Technical Documentation:

Frequently Asked Questions (FAQs):

What makes this backflow preventer lead-free?
It meets NSF/ANSI 61 certification, ensuring a low lead content below 0.25% for potable water safety.

Is this suitable for residential and commercial use?
Yes! It is designed for both residential and commercial applications, including municipal water systems, irrigation, and fire protection.

How often should I service this backflow preventer?
Annual testing and maintenance are recommended to ensure compliance and functionality.

Can I install this unit indoors?
Yes, but an air gap adapter and monitor switch may be required for indoor installations.

Does it comply with plumbing codes?
Absolutely! It is ASSE® 1013, IAPMO®, CSA®, AWWA, NSF/ANSI 61, and UL® classified.

Is this a new valve?
Yes, this is a brand new, never installed valve.

Is warranty included?
Yes, standard manufacturer warranties apply on all products.

Media:

Zurn Wilkins 975XL Repair Video:

Zurn Wilkins 975XL2 Troubleshooting Relief Valve Weep Hole Leakage Repair Video:

Zurn Wilkins 975XL2 Troubleshooting Reduced Pressure Principle Relief Valve Discharge:

🛒 Get the Zurn Wilkins 114-975XL2 RPZ Backflow Preventer Today for Reliable & Lead-Free Water Protection! 🚰

Payment & Security
American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Estimate Shipping

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Contact For Availability
Recently Viewed
Related Products